101218833 - RSS 36-I2-SD-ST

Description: Product type description:RSS 36 (1)-(2)-(3)-ST(1)withoutStandard codingI1Individual codingI2Individual coding, for multiple applications(2)DWith diagnostic outputSDWith serial diagnostic function(3)withoutwithout latchingRwith latching, latching force approx. 18 N
Description: Product type description:RSS 36 (1)-(2)-(3)-ST(1)withoutStandard codingI1Individual codingI2Individual coding, for multiple applications(2)DWith diagnostic outputSDWith serial diagnostic function(3)withoutwithout latchingRwith latching, latching force approx. 18 N
Productfeatures
  • Repeated individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • 1 x connector socket M12, 8-pole
  • Actuation from side
  • Max. 31 sensors can be wired in series.
  • serial diagnostic output
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Data
Ordering data

Product type description

RSS 36-I2-SD-ST

Article number (order number)

101218833

EAN (European Article Number)

4030661416335

eCl@ss number, version 9.0

27-27-24-03

eCl@ss number, version 11.0

27-27-24-03

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

TÜV

cULus

ECOLAB

EAC

FCC

IC

General data

Standards

IEC 60947-5-3

Coding

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Working principle

RFID

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

250 g

Time to readiness, maximum

2,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Serial diagnostics

Yes

Diagnostic output

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Safety functions

Yes

Cascadable

Yes

Integral system diagnostics, status

Yes

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Mechanical data

Actuating panels

lateral

Active area

lateral

Hysteresis (Switching distance), maximum

2 mm

Repeat accuracy R R

0.5 mm

Note (Repeat accuracy

Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm.

Mounting

A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance

12 mm

Assured switching distance "ON" S

10 mm

Assured switching distance "OFF" S

20 mm

Mechanical data - Connection technique

Type of connection

Connector M12, 8-pole

Note

The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

22 mm

Width of sensor

106.3 mm

Height of sensor

25 mm

Ambient conditions

Degree of protection

IP65

IP67

IP69

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Material temperature resistance of the cable (in motion), minimum

-10 °C

Material temperature resistance of the cable (at rest), minimum

-30 °C

Material temperature resistance (long-term), maximum

+105 °C

Resistance to vibration to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current, maximum I

100 mA

Rated operating voltage

24 VDC −15 % / +10 %

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

1 Hz

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Design of switching elements

p-type

Voltage drop U

1 V

Leakage current I

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Electrical data - Diagnostic outputs

Operating current

150 mA

Design of switching elements

p-type

Voltage drop U

2 V

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 60947-3

Status indication

Note (LED switching conditions display)

LED yellow: Operating condition

LED green: Supply voltage

LED red: Fault

Pin assignment

PIN 1

A1 Ue Brown

PIN 2

X1 Safety input 1 White

PIN 3

A2 GND Blue

PIN 4

Y1 Safety output 1 Black

PIN 5

serial diagnostic output OUT Grey

PIN 6

X2 Safety input 2 violet

PIN 7

Y2 Safety output 2 red

PIN 8

IN serial diagnostic input Pink

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

RST 36-1

RST 36-1-R

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Operating instructions and Declaration of conformity
  • RSS 36 / RST 36-1 ( V 2 )

    Download
TÜV certification
  • RSS 36 / RSS 36 AS

    Download
ECOLAB certification
  • RSS 36

    Download
UL Certificate
  • (384.6 kB, 08/01/2019)

    Download
Info
  • RSS 36 / RST … Actuating distances

    Download
Brochure
  • Electronic Safety Sensors and Solenoid Interlocks

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • ePLAN

    Download
  • CADENAS

    Download
  • SISTEMA

    Download