101181061 - CSS 14-34-S-SD-M-L

Description: Product type description:CSS (1)-34-(2)-(3)-(4)-M-(5)(1)12Actuation from top14Actuation from side(2)withoutStandard versionF0Input for enabling pushbutton, suitable for automatic startF1Input for reset pushbutton, with edge monitoring(3)Slateral active surfaceVfrontal active surface(4)DWith diagnostic outputSDSerial diagnostic output(5)Lwith connecting cableSTwith connector
Description: Product type description:CSS (1)-34-(2)-(3)-(4)-M-(5)(1)12Actuation from top14Actuation from side(2)withoutStandard versionF0Input for enabling pushbutton, suitable for automatic startF1Input for reset pushbutton, with edge monitoring(3)Slateral active surfaceVfrontal active surface(4)DWith diagnostic outputSDSerial diagnostic output(5)Lwith connecting cableSTwith connector
Productfeatures
  • 1 x Pre-wired cable 8-pole
  • Actuation from side
  • serial diagnostic output
  • Max. 31 sensors can be wired in series.
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Data
Ordering data

Product type description

CSS 14-34-S-SD-M-L

Article number (order number)

101181061

EAN (European Article Number)

4030661314853

eCl@ss number, version 9.0

27-27-24-03

eCl@ss number, version 11.0

27-27-24-03

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

IEC 60947-5-3

Working principle

inductive

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Glass-fibre, reinforced thermoplastic

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

295 g

Reaction time, maximum

30 ms

Duration of risk, maximum

60 ms

General data - Features

Serial diagnostics

Yes

Diagnostic output

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Safety functions

Yes

Cascadable

Yes

Integral system diagnostics, status

Yes

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of series-wiring of sensors

31

Mechanical data

Actuating panels

lateral

Active area

lateral

Switching distance actuator

Actuator CST 180-1 / CST 180-2: 10 mm

Actuator CST 34-S-1: 14 mm

Actuator CST 34-S-2: 14 mm

Actuator CST 34-S-3: 14 mm

Actuator CST 34-S-1: 12 mm

Actuator CST 34-S-2: 12 mm

Actuator CST 34-S-3: 12 mm

Actuator CST 180-1 / CST 180-2: 8 mm

Actuator CST 34-S-1: 17 mm

Actuator CST 34-S-2: 17 mm

Actuator CST 34-S-3: 17 mm

Actuator CST 180-1 / CST 180-2: 13 mm

Hysteresis (Switching distance), maximum

1.5 mm

Repeat accuracy R R

0.5 mm

Note (Repeat accuracy

Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle)

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance

10 mm

14 mm

Assured switching distance "ON" S

12 mm

8 mm

Assured switching distance "OFF" S

13 mm

17 mm

Mechanical data - Connection technique

Type of connection

Cable (Y-UL 2517), 8-pole

Length of cable

2 m

Cable section, maximum

8 x 0.35 mm²

Wire cross-section

22 AWG

Cable type

LiYY

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

35 mm

Width of sensor

27 mm

Height of sensor

108.2 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibration to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current, maximum I

100 mA

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

3 Hz

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Design of switching elements

p-type

Voltage drop U

0.5 V

Leakage current I

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Electrical data - Diagnostic outputs

Operating current

150 mA

Design of switching elements

p-type

Voltage drop U

5 V

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

A1 Ue Brown

PIN 2

X1 Safety input 1 White

PIN 3

A2 GND Blue

PIN 4

Y1 Safety output 1 Black

PIN 5

SD serial diagnostic output: Grey

PIN 6

X2 Safety input 2 violet

PIN 7

Y2 Safety output 2 red

PIN 8

IN serial diagnostic input Pink

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

CST 34-S-2

CST 34-S-3

CST 180-1

CST 180-2

CST 34-S-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Operating instructions and Declaration of conformity
  • CSS 34

    Download
TÜV certification
  • CSS 34 / CSP 34

    Download
BG-test certificate
  • CSS 34 / CSS 34F.

    Download
UL Certificate
  • (384.9 kB, 08/01/2019)

    Download
Brochure
  • Electronic Safety Sensors and Solenoid Interlocks

    Download
  • Electronic Safety Sensors and Solenoid Interlocks

    Download
  • TraceParts

    Download
  • ePLAN

    Download