161184327 - ZQ 900-11

Description: Product type description:ZQ 900-(1)(2)(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact(2)withoutwithout emergency-stop buttonNwith emergency-stop button
Description: Product type description:ZQ 900-(1)(2)(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact(2)withoutwithout emergency-stop buttonNwith emergency-stop button
Productfeatures
  • 3 cable entries M 20 x 1.5
  • Metal enclosure
  • one-side operation / wire up to 75 m long
  • Release push button
  • Position indicator
  • Robust design
  • Large wiring compartment
  • Twisting of towing eye not possible
  • External watertight collar
  • wire pull and breakage detection
Data
Ordering data

Product type description

ZQ 900-11

Article number (order number)

161184327

eCl@ss number, version 9.0

27-37-12-01

eCl@ss number, version 11.0

27-37-12-01

eCl@ss number, version 12.0

27-37-12-01

ETIM number, version 7.0

EC002026

ETIM number, version 6.0

EC002026

Approvals - Standards

Certificates

TÜV

EAC

General data

Standards

EN ISO 13850

IEC/EN 60947-5-1

IEC/EN 60947-5-5

Enclosure material

Zinc die-cast

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Material of the cover

Glass-fibre, thermoplastic

Length of the wire, maximum

75 m

Gross weight

1,300 g

General data - Features

Indicator lamp

No

Number of auxiliary contacts

1

Number of safety contacts

1

Safety classification - Safety outputs

B

100,000 Operations

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Length of sensor

69.7 mm

Width of sensor

71.5 mm

Height of the Sensor, minimum

220.3 mm

Height of the Sensor, maximum

236.3 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Relative humidity, maximum

95 %

Ambient conditions - Insulation values

Rated insulation voltage U

500 V

Rated impulse withstand voltage U

6 kV

Electrical data

Thermal test current

6 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

NO contact, NC contact

Switching principle

Snap switch element

Operating instructions and Declaration of conformity
  • ZQ 900

    Download
BG-test certificate
  • TQ 900 / ZQ 900 (ACE)

    Download
  • TQ 900 / ZQ 900 (SIPL)

    Download
  • TQ 900 / ZQ 900 (SISS)

    Download
Brochure
  • Pull-wire emergency stop switches and Pull-wire switches

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • CADENAS

    Download
  • SISTEMA

    Download