131188851 - AZM190-02/01RKN-24VDC

Description: Product type description:AZM190-(1)RK(2)(3)-(4)-(5)(1)02/01Magnet: 2 NC contacts; actuator: 1 NC contact02/02Magnet: 2 NC contacts; actuator: 2 NC contacts02/10Magnet: 2 NC contacts; actuator: 1 NO contact02/11Magnet: 2 NC contacts; actuator: 1 NC contact/1 NO contact11/01Magnet: 1 NC contact/1 NO contact; actuator: 1 NC contact11/02Magnet: 1 NC contact/1 NO contact; actuator: 2 NC contacts11/10Magnet: 1 NC contact/1 NO contact; actuator: 1 NO contact11/11Magnet: 1 NC contact/1 NO contact; actuator: 1 NC contact/1 NO contact(2)withoutPower to unlockAPower to lock(3)withoutWith manual release on the cover sideE0Without manual releaseE1With manual release from side (right)NEmergency releaseTEmergency exit(4)withoutwithout LED switching conditions displayGWith LED switching conditions display (for 24 V AC/DC only; cannot be combined with -E1 and -T)(5)24VACUs: 24 VAC24 VDCUs: 24 VDC48VACUs: 48 VAC110VACUs: 110 VAC230VACUs: 230 VAC
Description: Product type description:AZM190-(1)RK(2)(3)-(4)-(5)(1)02/01Magnet: 2 NC contacts; actuator: 1 NC contact02/02Magnet: 2 NC contacts; actuator: 2 NC contacts02/10Magnet: 2 NC contacts; actuator: 1 NO contact02/11Magnet: 2 NC contacts; actuator: 1 NC contact/1 NO contact11/01Magnet: 1 NC contact/1 NO contact; actuator: 1 NC contact11/02Magnet: 1 NC contact/1 NO contact; actuator: 2 NC contacts11/10Magnet: 1 NC contact/1 NO contact; actuator: 1 NO contact11/11Magnet: 1 NC contact/1 NO contact; actuator: 1 NC contact/1 NO contact(2)withoutPower to unlockAPower to lock(3)withoutWith manual release on the cover sideE0Without manual releaseE1With manual release from side (right)NEmergency releaseTEmergency exit(4)withoutwithout LED switching conditions displayGWith LED switching conditions display (for 24 V AC/DC only; cannot be combined with -E1 and -T)(5)24VACUs: 24 VAC24 VDCUs: 24 VDC48VACUs: 48 VAC110VACUs: 110 VAC230VACUs: 230 VAC
Productfeatures
  • Thermoplastic enclosure
  • Long life
  • Interlock with protection against incorrect locking.
  • 89 mm x 178 mm x 41 mm
  • Actuating head can be repositioned by 4 x 90°
  • 2 cable entries M 20 x 1.5
  • Wiring compartment
  • Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing
  • Sealing mechanism to prevent the ingress of dirt
  • Cut clamp termination
Data
Ordering data

Replacement article number

101188851

Product type description

AZM190-02/01RKN-24VDC

Article number (order number)

131188851

EAN (European Article Number)

8905236102042

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

CCC

EAC

General data

Standards

BG-GS-ET-19

EN 60947-5-1

Coding level according to ISO 14119

Low

Working principle

electromechanical

Enclosure material

Glass-fibre, reinforced thermoplastic

Material of the contacts, electrical

Silver

Gross weight

480 g

General data - Features

Power to unlock

Yes

Emergency release

Yes

Number of actuating directions

4

Number of cable glands

2

Number of safety contacts

3

Safety classification - Safety outputs

B

2,000,000 Operations

B

1,000,000 Operations

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Holding force

1,950 N

Latching force

20 N

Positive break force, minimum

20 N

Actuating speed, maximum

0.3 m/s

Mechanical data - Connection technique

Type of connection

Screw terminals

Cable entry

M20 cable gland

Cable section, minimum

1 x 0.5 mm²

Cable section, maximum

1 x 1.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Length of sensor

41 mm

Width of sensor

52 mm

Height of sensor

178 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+50 °C

Ambient conditions - Insulation values

Rated insulation voltage U

250 V

Rated impulse withstand voltage U

4 kV

Electrical data

Thermal test current

4 A

Rated control voltage

24 VDC

Required rated short-circuit current to EN 60947-5-1

1,000 A

Electrical power consumption, maximum

8.5 W

Switching principle

Creep circuit element

Switching frequency

1.2 /h

Electrical data - Safety contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

4 A

Electrical data - Auxiliary contacts

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

4 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

4 A

Other data

Note (applications)

sliding safety guard

removable guard

hinged safety guard

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions (supplementary sheet/quick guide)
  • (120.2 kB, 11/19/2019)

    Download
Operating instructions and Declaration of conformity
  • (661.5 kB, 12/15/2021)

    Download
UL Certificate
  • (397.9 kB, 09/23/2020)

    Download
TÜV certification
  • AZM 190 (KAS)

    Download
  • AZM 190 (SIPL)

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download