103032732 - AZM201Z-ST2-T-SD2P-A
- Brand: Schmersal
- Product Code: 103032732
- Power to lock
- Thermoplastic enclosure
- Max. length of the sensor chain 200 m
- Self-monitoring series-wiring
- Coding in accordance to ISO 14119 by using RFID-Technology
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Suitable for hinged and sliding guards
- Intelligent diagnosis
- Manual release
- Protection class IP66, IP67
- High holding force 2000
- symmetrical construction form, assembly on 40mm profiles
- OSSD safety outputs
- Emergency exit / Emergency release suitable for retrofitting
Data
Ordering data
Product type description | AZM201Z-ST2-T-SD2P-A |
Article number (order number) | 103032732 |
EAN (European Article Number) | 4030661529424 |
eCl@ss number, version 9.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 12.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
Certificates | TÜV cULus EAC FCC IC |
General data
Standards | EN ISO 13849-1 EN ISO 14119 IEC 60947-5-1 IEC 60947-5-3 IEC 61508 IEC 62061 |
Coding | Universal coding |
Coding level according to ISO 14119 | Low |
Working principle | RFID |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 596.1 g |
Time to readiness, maximum | 4,000 ms |
Duration of risk, maximum | 200 ms |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum | 0.5 ms |
General data - Features
Solenoid interlock monitored | Yes |
Serial diagnostics | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of safety contacts | 2 |
Number of series-wiring of sensors | 31 |
Safety classification - Interlocking function
Performance Level, up to | e |
Category | 4 |
PFH value | 1.90 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Safety classification - Guard locking function
Mission time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Holding force in accordance with EN ISO 14119 F | 2,000 N |
Holding force, maximum F | 2,600 N |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Mechanical data - Connection technique
Type of connection | Connector M12, 8-pole |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Ambient conditions
Degree of protection | IP67 IP66 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibration to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 26.4 VDC |
No-load supply current, maximum I | 50 mA |
Current consumption with magnet ON, average | 200 mA |
Current consumption with magnet ON, peak | 700 mA / 100 ms |
Operating current | 1,200 mA |
Switching frequency, approx. | 1 Hz |
Electrical data - Magnet control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) | 250 mA |
Voltage drop U | 4 V |
Leakage current I | 0.5 mA |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic outputs
Operating current | 50 mA |
Voltage drop U | 4 V |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |
Scope of delivery
Scope of delivery | Actuators must be ordered separately. Triangular key for AZM 201 |
Accessory