Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103025857 - AZM201B-I2-ST-T-AS-A-P

Description: Product type description:AZM201(1)(2)-ST-T-AS(3)P(1)ZSolenoid interlock monitoredNB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)withoutStandard codingI1Individual codingI2Individual coding, re-teaching enabled(3)withoutPower to unlockAPower to lockPPMagnet supply 24 VDC (AUX)
Description: Product type description:AZM201(1)(2)-ST-T-AS(3)P(1)ZSolenoid interlock monitoredNB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)withoutStandard codingI1Individual codingI2Individual coding, re-teaching enabled(3)withoutPower to unlockAPower to lockPPMagnet supply 24 VDC (AUX)
Productfeatures
  • Thermoplastic enclosure
  • High holding force 2000
  • 40 mm x 244 mm x 50 mm
  • Interlock with protection against incorrect locking.
  • Double-insulated
  • Long life
  • Integrated AS-Interface
  • Solenoid interlock with integrated AS-i Safety Interface
  • Universal repeatedly teachable or individual coding because of the RFID technology
  • I-variants with coding level HIGH to ISO 14119
Data
Ordering data

Product type description

AZM201B-I2-ST-T-AS-A-P

Article number (order number)

103025857

EAN (European Article Number)

4030661524177

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

EAC

FCC

IC

General data

Standards

EN 62026-2

EN ISO 13849-1

EN ISO 14119

IEC 60947-5-3

IEC 61508

IEC 62061

Coding

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Working principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

538.5 g

Time to readiness, maximum

4,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Latching

Yes

Manual release

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of actuating directions

2

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

1.81 x 10⁻⁹ /h

PFD value

1.59 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Holding force in accordance with EN ISO 14119 F

2,000 N

Holding force, maximum F

2,600 N

Latching force

30 N

Actuating speed, maximum

0.2 m/s

Tightening torque of the fixing screws, maximum

8 Nm

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

IP66

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Relative humidity, minimum

10 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

3

Electrical data

Switching frequency, maximum

1 Hz

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

100 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 3.0

AS-i Profile

S-7.B.F.E

AS-i, IO-Code

0x7

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Solenoid control

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Safety guard and actuator detected

AS-i Parameter bits, P1

Solenoid interlock locked

AS-i Parameter bits, P2

Magnet voltage in tolerance range

AS-i Parameter bits, P3

Internal device error (FID)

Note (AS-i Parameter bits)

FID: periphery error

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Electrical data - Auxiliary voltage

Rated operating voltage

24 VDC -15% / +10% (stabilised PELV)

Current consumption

500 mA

Status indication

Note (LED switching conditions display)

Status and diagnostics: Transmitter + receiver

(2) LED red: Internal device error

(3) LED yellow: Device condition

Pin assignment

PIN 1

AS-Interface +

PIN 2

Aux - (P)

PIN 3

AS-Interface -

PIN 4

Aux + (P)

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions and Declaration of conformity
  • (502.0 kB, 06/15/2021, C)

    Download
TÜV certification
  • AZ201 / AZM201

    Download