103003607 - RSS260-I2-D-ST
- Brand: Schmersal
- Product Code: 103003607
- Repeated individual coding with RFID technology
- Coding level "High" according to ISO 14119
- 1 x connector plug M8
- Frontal and lateral actuation enabled
- Thermoplastic enclosure
- Simple mounting without additional angle
- RFID-technology for needs-based protection against tampering
Data
Ordering data
Product type description | RSS260-I2-D-ST |
Article number (order number) | 103003607 |
EAN (European Article Number) | 4030661436432 |
eCl@ss number, version 9.0 | 27-27-24-03 |
eCl@ss number, version 11.0 | 27-27-24-03 |
ETIM number, version 7.0 | EC000030 |
ETIM number, version 6.0 | EC000030 |
Approvals - Standards
Certificates | TÜV cULus EAC FCC IC |
General data
Standards | IEC 60947-5-3 |
Coding | Individual coding, multiple teaching |
Coding level according to ISO 14119 | High |
Working principle | RFID |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring |
Enclosure material | Plastic, thermoplastic, self-extinguishing |
Active area | Glass-fibre, thermoplastic |
Gross weight | 61 g |
Time to readiness, maximum | 2,000 ms |
Reaction time, maximum | 100 ms |
Duration of risk, maximum | 200 ms |
General data - Features
Diagnostic output | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Cascadable | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 3 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Mechanical data
Actuating panels | lateral front side |
Active area | lateral front |
Hysteresis (Switching distance), maximum | 2 mm |
Repeat accuracy R R | 0.5 mm |
Note (Repeat accuracy | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm |
Mounting | A 20 mm screw length usually suffices to mount the sensor. When the mounting plates are used, we recommend 25 mm long screws. |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance S | front 12 mm lateral 9 mm |
Assured switching distance "ON", front | 10 mm |
Assured switching distance "OFF", front | 18 mm |
Assured switching distance "ON", side | 6 mm |
Assured switching distance "OFF", side | 15 mm |
Mechanical data - Connection technique
Type of connection | Connector M8 |
Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
Length of sensor | 29.5 mm |
Width of sensor | 39.2 mm |
Height of sensor | 18 mm |
Ambient conditions
Degree of protection | IP65 IP67 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +65 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibration to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Voltage type | DC (direct current) |
No-load supply current, maximum I | 100 mA |
Rated operating voltage | 24 VDC -15% / +10% |
Rated operating voltage, minimum | 20.4 VDC |
Rated operating voltage, maximum | 26.4 VDC |
Operating current | 600 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 1 Hz |
Electrical data - Safety digital outputs
Design of switching elements | p-type |
Voltage drop U | 1 V |
Leakage current I | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Electrical data - Diagnostic outputs
Operating current | 50 mA |
Design of switching elements | p-type |
Voltage drop U | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation | IEC 61000-6-4 |
EMC rating | IEC 60947-3 |
Status indication
Note (LED switching conditions display) | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
Pin assignment
PIN 1 | A1 U : White |
PIN 2 | X1 safety input 1: Brown |
PIN 3 | A2 GND: Green |
PIN 4 | Y1 safety output 1: Yellow |
PIN 5 | OUT Diagnostic output OUT Grey |
PIN 6 | X2 safety input 2: Pink |
PIN 7 | Y2 safety output 2: Blue |
PIN 8 | IN without function: Red |