Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101209104 - AZM 161 Z ST1-AS RA

Description: Product type description:AZM 161 (1) (2)-AS (3)(4)(5)(6)(1)ZGuard locking monitored >NB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)ST1Bottom-side connectorST2Connector at the right-hand side(3)withoutLatching force 5 NRLatching force 30 N(4)withoutPower to unlockAPower to lock(5)withoutMagnet supply from AS-InterfacePMagnet supply 24 VDC (AUX)(6)withoutManual releaseNEmergency releaseTEmergency exit
Description: Product type description:AZM 161 (1) (2)-AS (3)(4)(5)(6)(1)ZGuard locking monitored >NB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)ST1Bottom-side connectorST2Connector at the right-hand side(3)withoutLatching force 5 NRLatching force 30 N(4)withoutPower to unlockAPower to lock(5)withoutMagnet supply from AS-InterfacePMagnet supply 24 VDC (AUX)(6)withoutManual releaseNEmergency releaseTEmergency exit
Productfeatures
  • Solenoid supply AUS AS interface
  • Guard locking monitored
  • Manual release
  • Solenoid interlock
  • Thermoplastic enclosure
  • High holding force 2000
  • 130 mm x 90 mm x 30 mm
  • Interlock with protection against incorrect locking.
  • Double-insulated
  • Long life
  • Integrated AS-Interface
Data
Ordering data

Product type description

AZM 161 Z ST1-AS RA

Article number (order number)

101209104

EAN (European Article Number)

4030661396477

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

EAC

General data

Standards

EN 60947-5-1

EN 62026-2

EN ISO 13849-1

IEC 61508

Working principle

electromechanical

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Gross weight

465 g

Reaction time, maximum

100 ms

General data - Features

Power to lock

Yes

Solenoid interlock monitored

Yes

Manual release

Yes

Integral system diagnostics, status

Yes

Number of actuating directions

3

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Actuating play in direction of actuation

5.5 mm

Holding force

2,000 N

Latching force

30 N

Actuating speed, maximum

2 m/s

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Connector position

Bottom

Mechanical data - Dimensions

Length of sensor

30 mm

Width of sensor

130 mm

Height of sensor

90 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 Hz ... 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Switching frequency

1,000 /h

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

250 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 2.1

AS-i Profile

S-7.B.F.E

AS-i, IO-Code

0x7

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Solenoid control

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Actuator detected

AS-i Parameter bits, P1

Solenoid interlock locked

AS-i Parameter bits, P2

Magnet voltage in tolerance range

AS-i Parameter bits, P3

Error message - locking/unlocking of the solenoid interlock blocked

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

FID: periphery error

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Status indication

Note (LED switching conditions display)

(1) LED yellow: Channel 2 / AS-i SaW Bit 2.3

(2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected

(3) LED yellow: Channel 1 / AS-i SaW Bit 0.1

Other data

Note (applications)

sliding safety guard

removable guard

hinged safety guard

Pin assignment

PIN 1

AS-i +

PIN 2

Aux - (P)

PIN 3

AS-Interface -

PIN 4

Aux + (P)

Operating instructions and Declaration of conformity
  • AZM 161 AS

    Download
UL Certificate
  • (385.0 kB, 08/01/2019)

    Download
TÜV certification
  • AZM 161 AS

    Download
SISTEMA-VDMA library
  • (109.5 kB, 11/11/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download