101189088 - CSS 12-34F0-V-D-M-ST
- Brand: Schmersal
- Product Code: 101189088
- 1 x connector plug M12, 8-pole
- without edge monitoring of the enabling pushbutton, suitable for automatic start
- To control positive-guided relay without downstream safety monitoring module
- Suitable as individual or terminal device in series-wiring of standards sensors to replace a safety monitoring module
- Self-monitored series-wiring of up to 30 CSS 34 sensors and one CSS 34F0/F1 sensor for control category 4 to ISO 13849-1
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Misaligned actuation possible
- 27 mm x 108.2 mm x 35 mm
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Data
Ordering data
Product type description | CSS 12-34F0-V-D-M-ST |
Article number (order number) | 101189088 |
EAN (European Article Number) | 4030661354880 |
eCl@ss number, version 9.0 | 27-27-24-03 |
eCl@ss number, version 11.0 | 27-27-24-03 |
ETIM number, version 7.0 | EC000030 |
ETIM number, version 6.0 | EC000030 |
Approvals - Standards
Certificates | TÜV cULus EAC |
General data
Standards | IEC 60947-5-3 |
Working principle | inductive |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Active area | Glass-fibre, reinforced thermoplastic |
Gross weight | 146 g |
Reaction time, maximum | 30 ms |
Duration of risk, maximum | 60 ms |
General data - Features
Diagnostic output | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Cascadable | Yes |
Input for enabling pushbutton, suitable for automatic start | Yes |
Integral system diagnostics, status | Yes |
Number of LEDs | 3 |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Number of series-wiring of sensors | 31 |
Mechanical data
Actuating panels | Actuation from top |
Active area | front side |
Switching distance actuator | Actuator CST 34-V-1: 12 mm Actuator CST 34-S-2: 10 mm Actuator CST 34-S-3: 15 mm Actuator CST 180-1 / CST 180-2: 12 mm Actuator CST 34-V-1: 10 mm Actuator CST 34-S-2: 8 mm Actuator CST 34-S-3: 13 mm Actuator CST 180-1 / CST 180-2: 10 mm Actuator CST 34-V-1: 15 mm Actuator CST 34-S-2: 16 mm Actuator CST 34-S-3: 18 mm Actuator CST 180-1 / CST 180-2: 16 mm |
Hysteresis (Switching distance), maximum | 1.5 mm |
Repeat accuracy R R | 0.5 mm |
Note (Repeat accuracy | Axial offset: the front face allows for an axial misalignment (z) of max. ± 8 mm (see figure: operating principle). |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance | 10 mm 12 mm 15 mm |
Assured switching distance "ON" S | 10 mm 13 mm 8 mm |
Assured switching distance "OFF" S | 15 mm 16 mm 18 mm |
Mechanical data - Connection technique
Type of connection | Connector plug M12, 8-pole |
Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
Length of sensor | 35 mm |
Width of sensor | 27 mm |
Height of sensor | 108.2 mm |
Ambient conditions
Degree of protection | IP65 IP67 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibration to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Voltage type | DC (direct current) |
No-load supply current, maximum I | 100 mA |
Operating current | 600 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 3 Hz |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) | 250 mA |
Output current, (fail-safe output), maximum | 0.25 A |
Design of switching elements | p-type |
Voltage drop U | 0.5 V |
Leakage current I | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Electrical data - Diagnostic outputs
Design of switching elements | p-type |
Voltage drop U | 5 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Electrical data - Electromagnetic compatibility (EMC)
Interfering radiation | IEC 61000-6-4 |
EMC rating | IEC 61000-6-2 |
Pin assignment
PIN 1 | 1A1 Ue: (1) |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output OUT |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN without function |
Scope of delivery
Scope of delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | CST 34-V-1 CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2 |
Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |