Description: Product type description:(1)(2) 3(3)5-(4)Z(5)-(6)-(7)-(8)-(9)(1)ZSnap actionTSlow action (not for AF/S)(2)SPlunger SRRoller plunger RHRoller lever H10HRod lever 10H7HRoller lever 7H1KOffset roller lever 1K3KAngle roller lever 3KRMSBrass roller(3)3slim design215large design(4)111 NO contacts/1 NC contact022 NC contact202 NO contacts (not suitable for safety applications)01/011 NC contact left / 1 NC contact right121 NO contact/2 NC contacts033 NC contact(5)HSlow action with staggered contactsUESlow action with overlapping contacts22722272 Special roller bolt with collar1183with aluminium rod1699-1 Exterior stainless steel bolts and clamp(6)G24with LED (7)withoutCable entry M20NPTCable entry NPT 1/2STM12 connector with A-coding (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits.)ST-2310M12 connector with B-coding (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits.)(8)2138Roller lever 7H for position switches with safety function(9)1637Gold-plated contacts
Description: Product type description:(1)(2) 3(3)5-(4)Z(5)-(6)-(7)-(8)-(9)(1)ZSnap actionTSlow action (not for AF/S)(2)SPlunger SRRoller plunger RHRoller lever H10HRod lever 10H7HRoller lever 7H1KOffset roller lever 1K3KAngle roller lever 3KRMSBrass roller(3)3slim design215large design(4)111 NO contacts/1 NC contact022 NC contact202 NO contacts (not suitable for safety applications)01/011 NC contact left / 1 NC contact right121 NO contact/2 NC contacts033 NC contact(5)HSlow action with staggered contactsUESlow action with overlapping contacts22722272 Special roller bolt with collar1183with aluminium rod1699-1 Exterior stainless steel bolts and clamp(6)G24with LED (7)withoutCable entry M20NPTCable entry NPT 1/2STM12 connector with A-coding (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits.)ST-2310M12 connector with B-coding (Caution! According to EN 60204-1, the versions with connector must only be used in PELV circuits.)(8)2138Roller lever 7H for position switches with safety function(9)1637Gold-plated contacts
Productfeatures
  • 1 Cable entry M 20 x 1.5
  • Metal enclosure
  • Wide range of alternative actuators
  • Good resistance to oil and petroleum spirit
  • 40,5 mm x 76 mm x 38 mm
  • Actuator heads can be repositioned by 4 x 90°
  • Design to EN 50041
Data
Ordering data

Product type description

TS 335-02Z

Article number (order number)

101082520

EAN (European Article Number)

4030661063935

eCl@ss number, version 9.0

27-27-26-01

eCl@ss number, version 11.0

27-27-26-01

eCl@ss number, version 12.0

27-27-26-01

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

Approvals - Standards

Certificates

cULus

CCC

EAC

General data

Housing construction form

Norm construction design

Actuator type to DIN EN 50041

B

Enclosure material

Light alloy die-casting

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Gross weight

175 g

General data - Features

Safety functions

Yes

Number of safety contacts

2

Safety classification - Safety outputs

B

20,000,000 Operations

Mechanical data

Actuating element

Plunger

Mechanical life, minimum

30,000,000 Operations

Actuating force, minimum

17 N

Actuating speed, maximum

0.5 m/s

Note (Switchover time)

Switchover time in accordance with actuating speed

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Length of sensor

38 mm

Width of sensor

40.5 mm

Height of sensor

103.5 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+80 °C

Ambient conditions - Insulation values

Rated insulation voltage U

500 V

Rated impulse withstand voltage U

6 kV

Operating instructions (supplementary sheet/quick guide)
  • Z 332 , Z/T 335 , Z/T 336 , Z/T 355

    Download
EC Declaration of conformity
  • Z/T 235 , Z/T 236 , Z/T 255 , Z/T 256 , Z/T 335 , Z/T 336 , Z/T 355 , Z 332

    Download
UL Certificate
  • UL-335,336,355,3350

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download